X-ray DIOX-602
Portable X-ray machine DIOX-602 (ДИОКС-602) – a portable dental X-ray system in the form of an X-ray generator with microprocessor control – has the following characteristics:
Device characteristics
1. Since the X-ray generator uses a high-frequency inverter, it provides a stable output of direct current radiation with minimal pulsations. This allows for improved picture quality compared to a similar type of AC device.
2. By reducing losses due to the use of stable constant tension, the DIOX-602 system allows you to take pictures with a lower dose of X-ray radiation, thereby protecting the patient, user and operator from the harmful effects of X-rays.
3. Having a built-in wireless system, the DIOX-602 system greatly facilitates the operating conditions of the device and makes the operator's work more comfortable.
4. The use of an X-ray generator of a new design leads to a decrease in the volume and weight of the device (patent applied for).
Device specifications, technical characteristics
1. Mark Class II
2. Classification Working part of Type B device
3. X-ray generator:
Lamp voltage 60 kV (fixed)
Lamp current 2mA (fixed)
High voltage generator: high frequency inverter
X-ray control method: control through a microprocessor
Time setting range 0.01 ― 1.6 seconds (0.01 s ― step)
4. X-ray lamp
Type ― Stationary anode X-ray lamp
Lamp model: D-081BS (Toshiba, Japan)
The focal size of the lamp is 0.8 mm
Working voltage of the lamp: 50 - Maximum 65 kV
Maximum output power (at 1.0 sec)--------- 600 W
Aiming angle------------------------------------------------ ----- 20°
Full length----------------------------- 77 mm
Maximum diameter--------------38 mm
Weight (Approximately)----------------- 140 g
X-ray coverage area------ 354x354 mm at SID 490 mm
Cooling method: oil immersion (60 º C max.) and convection oil
Lamp cartridge-------------------- ― an insulating cylinder
General filtering------------------------------------------------ ----------- 1.6 mm Al
(internal filtration: 0.8 mm AL, fixed added filtration - 0.8 mm AL)
The maximum voltage of the lamp--------------------------------------------- 65kV
The maximum inverse voltage of the lamp is 75 kV
The minimum voltage of the lamp--------------------------------------------- 50 kV
The maximum current of the lamp---------------- -19 mA
Maximum glow current------------------------------------------------------------ --------- 2.0 A
Incandescence voltage at the maximum voltage current ------------------ 2.9 ― 4.0 V
Thermal characteristics:
Heat capacity of the anode------------------ 6.0 kJ (8.5 kHU – Hausfield units)
The maximum rate of heat dissipation of the anode is 128 W (180 HU/sec)
5. Display - LCD display
6. Scattering "Source - skin" ― 110 mm
7. X-ray radiation field - 65 mm (Circle)
8. Weight 1.8 kg
9. Main body size: 135(Width)x150(Depth)x175(Height)
10. Voltage is used
Battery ― Lithium - polymer battery (24 V DC)
Charger ― MW125KA2402F52 AULT INC
(Input: 100-240V ― 50-60Hz 1.0 A Output: Direct current 24V 1.7 A)
There are no reviews for this product, be the first to leave your review.
No questions about this product, be the first and ask your question.